Parameter |
Range |
Sensor |
Sensor Output |
Notes |
Command |
Format |
| Wind Velocity | 0 to 100 m/s;
0 to 360 Deg. Rel. |
R.M. Young, 09101 Wind Monitor RE | Serial Interface | Vector average 60 1 sec samples; direction relative to index, corrected by LENA heading. Update 1/min. | #WND01C | Speed, Dir.
ww.wddd.d |
| Atmospheric Pressure | 800 to 1000 +/-.3mb | AIR-SB-2 | Serial Interface, ASCII output | Median of 160 samples taken 1/sec. DBCP (WOCE) algorithm. Update hourly | #BPR01C | pppp.p |
| Relative Humidity | 0.8 to 100 +/-1%RH | Vaisala HMP45A | 0 to 1 VDC | Mounted with HMP45D in 2212 radiation shield. Instantaneous sample. Update 1/min. |
#HRH01C |
RH. Temp. rh.rhrtt.ttt |
| Air Temperature | -40 to 60 +/-.2C | Vaisala HMP45D | 0 to 1 VDC | Mounted with HMP45A in 2212 radiation shield. Instantaneous sample. Update 1/min | ||
| SST | 0 to 25 +/-.05 C | BetaTherm Thermistor, ss-316probe. | Average 15 samples taken 1/min. Update 1/15 min. (WOCE) | #SST01C | tt.ttt |